Hi Fiore, Having spent a little more time with the meter plug-in, one thing now stands out to me as something that I feel is incorrect about the threshold parameter. Given that we're dealing primarily with full scale metering, most of us think of the meters as being 0 dB FS, thus, with the Threshold parameter having a scale up to plus 6.02 dB, it's inconsistent with what most people consider the meter range to be. Of course, some people (but usually not blind users) could be using a vU scale. For blind users, however, I think it's best to have that threshold have a maximum setting of 0 db FS. I think it's safe to say that users are not so much concerned with average levels but rather being alerted when approaching a designated threshold and that threshold will almost invariably be relative to 0 dB full scale.
Anyway, my two cents. Best, Slau -- You received this message because you are subscribed to the Google Groups "Pro Tools Accessibility" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. For more options, visit https://groups.google.com/d/optout.
