On Wed, Jun 15, 2022 at 04:22:14PM +0200, Enrico Jorns wrote: > Enable it by default so that default installation can benefit from this. > Can be deactivated for saving space or for deactivating network > functionality. > Web server must support HTTP range requests for this and NBD support > must be enabled in kernel. > > Signed-off-by: Enrico Jorns <[email protected]> > --- > rules/rauc.in | 11 +++++++++++ > rules/rauc.make | 1 + > 2 files changed, 12 insertions(+) > > diff --git a/rules/rauc.in b/rules/rauc.in > index aee162b83..832967b44 100644 > --- a/rules/rauc.in > +++ b/rules/rauc.in > @@ -13,6 +13,7 @@ menuconfig RAUC > select BUSYBOX_FEATURE_SEAMLESS_GZ if BUSYBOX_TAR > select DBUS if RAUC_SERVICE > select LIBCURL if RAUC_NETWORK > + select LIBNL3 if RAUC_STREAMING > select JSON_GLIB if RAUC_JSON > select UTIL_LINUX_NG_LIBFDISK if RAUC_GPT > select SQUASHFS_TOOLS if RUNTIME > @@ -44,6 +45,16 @@ config RAUC_NETWORK > Note that network is primarily designed to be used for RAUC'S casync > capabilities, not for fetching full bundles. > > +config RAUC_STREAMING > + bool > + prompt "Enable streaming support" > + default y
Why 'default y'? I think most users won't need this. Michael > + select RAUC_NETWORK > + help > + Enables built-in HTTP(S) streaming support that allows RAUC to > + access remote bundles via http/https and write images without the > + need for intermediate storage on the target. > + > config RAUC_JSON > bool > prompt "JSON support" > diff --git a/rules/rauc.make b/rules/rauc.make > index 46d196bed..820583e59 100644 > --- a/rules/rauc.make > +++ b/rules/rauc.make > @@ -43,6 +43,7 @@ RAUC_CONF_OPT := \ > --disable-valgrind \ > --$(call ptx/endis,PTXCONF_RAUC_SERVICE)-service \ > --$(call ptx/endis,PTXCONF_RAUC_NETWORK)-network \ > + --$(call ptx/endis,PTXCONF_RAUC_STREAMING)-streaming \ > --$(call ptx/endis,PTXCONF_RAUC_JSON)-json \ > --$(call ptx/endis,PTXCONF_RAUC_GPT)-gpt \ > --with-systemdunitdir=/usr/lib/systemd/system \ > -- > 2.30.2 > > > -- Pengutronix e.K. | | Steuerwalder Str. 21 | http://www.pengutronix.de/ | 31137 Hildesheim, Germany | Phone: +49-5121-206917-0 | Amtsgericht Hildesheim, HRA 2686 | Fax: +49-5121-206917-5555 |