> ...  but on a quick
> glance, I think the name of the resample method is left behind after the
> move, even if a resampler is not being used, but the actual resampler is
> indeed freed and reset.

Many thanks, Col!
I think you're right that the resampler is not being used after the move and 
only the name of the resampler method is left. I tried your patch and the 
resample method become right as 'null' for the GTalk 8000HZ mono input to the 
Bluetooth HSP sink. So resample does not really exist and cannot the root cause 
why the voice I hear is abnormal, seconds of voice and long silent interval.

I need to check the sink input data of the GTalk. There are multiple routing 
for this input: at first the Bluetooth A2DP sink, then to ALSA sink because 
A2DP sink is removed on profile switch from A2DP to HSP, and then to Bluetooth 
HSP sink. Is it possible that some input data are lost after the input stream 
is connected to the HSP sink, maybe for some reason as buffer overflow?

Thanks
Amanda


_______________________________________________
pulseaudio-discuss mailing list
[email protected]
http://lists.freedesktop.org/mailman/listinfo/pulseaudio-discuss

Reply via email to