29.01.2015 03:14, David Henningsson wrote:
The resampler framework just forwards the request to the lfe filter.
There are no resampler impl that can rewind yet, so just reset the
resampler impl instead of properly rewinding yet.
Note: Rewinds on the resampler happens very rarely - since this is
done on the sink-input side rather than the sink side, and PA keeps
a copy of already processed material, then this can only happen if
the client actively rewinds. And I don't know of any application that
actually uses that feature...
Signed-off-by: David Henningsson <[email protected]>
---
+void pa_resampler_rewind(pa_resampler *r, size_t amount) {
This needs more documentation, and maybe even a different signature. At
least, what amount are we talking about? Input or output samples? How do
I convert to the other units?
Basically, a proper signature is what would allow this code in
pa_sink_input_process_rewind to be removed:
/* Transform into local domain */
if (i->thread_info.resampler)
max_rewrite =
pa_resampler_request(i->thread_info.resampler, max_rewrite);
...because the call to pa_resampler_request() is only valid for
appending, not for rewinding samples.
--
Alexander E. Patrakov
_______________________________________________
pulseaudio-discuss mailing list
[email protected]