--- Begin Message ---
Hi,
You need to route traffic between LAN network and Ceph network, so that
this works. When you have all monitors using ceph network IPs, undo the
routing.
Cheers
El 9/1/23 a las 10:14, Piviul escribió:
Hi all, during the CEPH installation I have dedicated a 10Gb network
to CEPH but I fear I wrong the monitors and managers IPs because they
are referring to the LAN IPs PVE nodes instead of using the IPs of the
CEPH nodes of the CEPH dedicated network. To solve this problem can I
first of all create the monitors/managers on the dedicated CEPH
network and then remove the olds monitors/managers having LAN IPs?
This operation is safely?
Piviul
_______________________________________________
pve-user mailing list
[email protected]
https://lists.proxmox.com/cgi-bin/mailman/listinfo/pve-user
Eneko Lacunza
Zuzendari teknikoa | Director técnico
Binovo IT Human Project
Tel. +34 943 569 206 |https://www.binovo.es
Astigarragako Bidea, 2 - 2º izda. Oficina 10-11, 20180 Oiartzun
https://www.youtube.com/user/CANALBINOVO
https://www.linkedin.com/company/37269706/
--- End Message ---