On Fri, 14 Dec 2007, Ben Lau wrote:

In fact , only the setting of AGC is not preserved. By looking through
the source code , I found that AGC is set to auto mode inside the
pwc_video_open. Therefore , no matter what value you have picked
inside camstream, it will restore to auto mode automatically.

Becoz I need this feature for a demonstration urgently, I have fixed
it by myself. The patch is attached in my email.

(Based on the source code come with 2.6.20.6 kernel)

ah sorry for duplicating the solution, I didn't see this mail.

 _ _ __ ___ _____ ________ _____________ _____________________ ...
| Mathieu Bouchard - tél:+1.514.383.3801, Montréal QC Canada
_______________________________________________
pwc mailing list
pwc@lists.saillard.org
http://lists.saillard.org/mailman/listinfo/pwc

Reply via email to