Hello Everyone,
I have a question regarding the order of accuracy of the ACM method; Have you done any tests using the method of manufactured solutions ( published or otherwise) ? I tried the 2D taylor green benchmark but the order of accuracy I am getting is nowhere near what it should be. When comparing with exact solution I used the solution points directly not the subdivided solution in the vtu file to avoid interpolation issues polluting the order of accuracy Also regarding the ACM, how would one obtain the residual of the continuity and momentum equations? Pseudo-stats only report the change between two consecutive pseudo iterations Regards, M Kamra -- You received this message because you are subscribed to the Google Groups "PyFR Mailing List" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. To view this discussion on the web, visit https://groups.google.com/d/msgid/pyfrmailinglist/fc58961d-02b2-4e7b-a05b-62af91f93537n%40googlegroups.com.