Hi Sébastien,

On Mon, 02 Mar 2009 18:21:15 +0100, sconill...@chimie.u-strasbg.fr wrote:

> Hi all (for the second time today ...),
> 
> I have a problem using the "fit" function. When I try to do this :
> 
> > fit (fittest1 and resn P and !h.), (2VT4 and resn P and !h.)
> 
> I have this message error :
> 
> "ExecutiveRMS-Error: No atoms selected."
> 
> which seems very strange to me because doing something like :
> 
> > select d1, (fittest1 and resn P and !h.)
> or
> > select d2, (2VT4 and resn P and !h.)
> returns
> "Selector: selection "d1" (or "d2") defined with 21 atoms."
> 
> Any idea ?

Do (fittest1 and resn P and !h) and (2VT4 and resn P and !h.) have the same
list of atoms with the same residue number, chain and atom names?  If not,
then you will get that sort of message.

Cheers,
Rob
-- 
Robert L. Campbell, Ph.D.
Senior Research Associate/Adjunct Assistant Professor 
Botterell Hall Rm 644
Department of Biochemistry, Queen's University, 
Kingston, ON K7L 3N6  Canada
Tel: 613-533-6821            Fax: 613-533-2497
<robert.campb...@queensu.ca>    http://pldserver1.biochem.queensu.ca/~rlc

Reply via email to