Hi all, I'm on a PC (windows 7) with the latest incentive 1.7.6.0 version and I have seen this problem several times. I have been looking at various structures both pdb downloads and local X-ray or homology generated files. For example looking at 4xk9, I measure a distance between the ligand and protein which is fine. However when I want to do something like say right click on a residue (to identify it or) show sticks and the residue number/name is definitely not the one being clicked on, i.e. Trp147 is now stating it is His1 (which it is clearly not). I have had this problem occur numerous times with different proteins and it is a problem as I now need to simply restart the program.
Saving the session maintains the problem. Then selecting the residue in sequence view seems to fix the issue but only for that residue.... Any thoughts? J _________________________________ Joel Tyndall, PhD Associate Professor in Medicinal Chemistry National School of Pharmacy University of Otago PO Box 56 Dunedin 9054 New Zealand Skype: jtyndall Ph: +64 3 479 7293
------------------------------------------------------------------------------
_______________________________________________ PyMOL-users mailing list (PyMOL-users@lists.sourceforge.net) Info Page: https://lists.sourceforge.net/lists/listinfo/pymol-users Archives: http://www.mail-archive.com/pymol-users@lists.sourceforge.net