Maarten Wiltink wrote:
"Sanal, Arjun (NSN - IN/Bangalore)" <[email protected]> wrote in message
news:[email protected]...

[...]
The setup is a blade server, which has one master blade server which
runs the ntp server. All other blades sync the time from this master.
The master itself gets it time from a higher ntp server. The problem
is when the master says that it is not suitable for synchronization,
the client blades shouldn't reject it. If they, do all the blades
will end up with different time.

Configure the local clock as a source at high stratum on the master.
"server 127.127.1.0 stratum 10"

People will now fall all over you, and me, yelling that this is
anathema, but you have explained to my satisfaction what you want,
and this is how you do it.

I'm not going to fall over you since I absolutely agree that this is the easiest solution for such cases. ;-)

Martin
--
Martin Burnicki

Meinberg Funkuhren
Bad Pyrmont
Germany

_______________________________________________
questions mailing list
[email protected]
http://lists.ntp.org/listinfo/questions