Hi John,

The mica caps in green plastic shown in your picture were made by Micamold.
I also have few of those in the spare IF modules I have.
But I never found a single one failing up to now.
The mica caps in the C327 position that were reported failing (which seemingly 
generated the recommendation to change those on sight) were made by 
Cornell-Dubilier and are older than your "green ones".
IMHO, it is not necessary to replace them all, and maybe the originally used 
one at the C327 position was perfectly good initially.

Which is very bad in the C327 case is to use a ceramic capacitor which is not a 
NPO (C0G) one.
And even there, some will not fill the bill, having a ESR value higher than a 
mica one.
Using a high ESR capacitor in a parallel resonant circuit kills the Q of the 
circuit and the gain of the related stage.

73, Jacques, VE2JFE in Montreal