We're working with a group for multiple POP access and have run into a port problem. We have set all our equipment to the new 1812/1813 port requirements. However, this company still uses 1645/1646 in their Merit RADIUS and NAS equipment. They have an entry as follows for us: type=NONE:PROXY+APPEND. Obviously I can change back to the old numbers (not desirable), I can have them enter 1812,1813 into their RADIUS (this will work as far as auth requests go, but no accounting info shows up in the detail file, just in the debug logfile. For some reason their requests show up as coming from port 32770). What I'm wondering is if there is any way you can add the AuthPort and AcctPort syntax into the Client clauses. This would seem to make Radiator even more extensible and solve configuration issues such as the one described above. (For the record, I tried just putting the clauses in, but I get a keyword error currently.) Thanks for any help offered. Craig Thompson ---------------------------------------------------------------------- WingNET Internet Services, P.O. Box 3000 // Cleveland, TN 37320-3000 423-559-LINK (v) 423-559-5444 (f) http://www.wingnet.net ---------------------------------------------------------------------- The careful application of terror is also a form of communication. === To unsubscribe, email '[EMAIL PROTECTED]' with 'unsubscribe radiator' in the body of the message.