I'm testing a radius client module in order to allow other services (www, ftp, etc) to use only one centralized user database. It works just fine but for some users where I have check-items (like NAS-Port-Type=Async) the authentication fails because I'm not including this information in the Access-Request. I can solve my problem having a similar database without check-items in the users entries, but I would prefer not to go this way. I tried to use as "Service-Type" in the Access-Request "Authenticate-Only" with no result. The Radius RFC has the following information regarding "Authenticate-Only" Authenticate-Only - Only Authentication is requested, and no authorization information needs to be returned in the Access-Accept (typically used by proxy servers rather than the NAS itself). My understanding is that if I send an Access-Request with "Authenticate Only" the only check-item used to validate the user should be the password. If the password is ok Radiator should reply with an Access-Accept with no reply items; if the password is not ok Radiator should reply with an Access-Rejected. Apparently Radiator is ignoring the "Authenticate-Only" when I include it in the Access-Request. Any suggestions to solve my problem ? Many thanks in advance, --- Rui Cohen === Archive at http://www.thesite.com.au/~radiator/ To unsubscribe, email '[EMAIL PROTECTED]' with 'unsubscribe radiator' in the body of the message.