Greg,
I am passing these values and users cannot go anywhere or authenticate. one
difference in the radius users file that works versus this exported one from
Plat is in the User-Service-Type attribute.
Are you saying I do not need to pass these as a minimum?
>From Plat and Radiator via exported RADIUS users file:
Port-Limit=1,
Framed-Protocol=PPP,
Framed-Address=255.255.255.254,
Framed-Netmask=255.255.255.0,
User-Service=Framed-User,
Framed-Routing=None,
Framed-Compression=Van-Jacobsen-TCP-IP,
Framed-MTU=1500,
Session-Timeout=21600,
Idle-Timeout=900
>From RADIUS users file that is currently working with Livingston 2.1 on
Linux:
User-Service-Type = Framed-User,
Framed-Protocol = PPP,
Framed-Address = 255.255.255.254,
Framed-Netmask = 255.255.255.255,
Framed-Routing = None,
Framed-Compression = Van-Jacobsen-TCP-IP,
Framed-MTU = 1500
Session-Timeout = 21600,
Idle-Timeout = 900,
Port-Limit=1
I will start another thread on configurng the AS5200s if you don't mind
giving me a little assistance there. I believe our pool IPs are being
spoofed and I am not exactly sure how to stop it. I also have some
differences in my config.
Thanks again,
Rob Page
>>> Greg Kornatowsky <[EMAIL PROTECTED]> 11/25/99 12:14:43 PM >>>
This sounds like a Cisco problem. The only attrubutes your Radius server
needs to send the AS5200 is "Framed Protocol=PPP" and "User Service=Framed
User". Here is what my Cisco config looks like (minus any secrets).
Hope this helps you out.
Greg Kornatowsky
ZooLink
----- Original Message -----
From: "Greg Kornatowsky" <[EMAIL PROTECTED]>
To: "'Robert Page'" <[EMAIL PROTECTED]>
Sent: Thursday, November 25, 1999 12:14 PM
Subject: RE: (RADIATOR) Users Cannot Route After Connecting
> This sounds like a Cisco problem. The only attrubutes your Radius server
> needs to send the AS5200 is "Framed Protocol=PPP" and "User Service=Framed
> User". Here is what my Cisco config looks like (minus any secrets).
>
> Hope this helps you out.
>
> Greg Kornatowsky
> ZooLink
>
===
Archive at http://www.thesite.com.au/~radiator/