Hello Erik -
On Wed, 09 Feb 2000, Erik Meitner wrote:
> We have a USR TotalControl Chassis that still produces these messages:
>
> Tue Feb 8 15:05:07 2000: INFO: Duplicate request id 236 received from
> 11.22.33.44: ignored
>
> even though IgnoreAcctSignature is in the <Client xxx> section. Does this
> mean we are still loosing accounting data?
>
No. It probably means you have a mis-match between the NAS radius timeout
period, and/or the Client DupInterval parameter.
Note that I see many people using DupInterval 0 in their Clients. This should
only be used for localhost for testing. More reasonable values are anything up
to 10 seconds (the default in Radiator 2.14.1 is 2 seconds).
hth
Hugh
--
Radiator: the most portable, flexible and configurable RADIUS server
anywhere. SQL, proxy, DBM, files, LDAP, NIS+, password, NT, Emerald,
Platypus, Freeside, TACACS+, PAM, external, etc etc on Unix, Win95/8,
NT, Rhapsody
===
Archive at http://www.thesite.com.au/~radiator/
To unsubscribe, email '[EMAIL PROTECTED]' with
'unsubscribe radiator' in the body of the message.