It seems like I found some of the answers myself. Deleting from the
SYS_DEFAULT table is not possible. So I set the COLUMN_ID of the double
records to NULL in this table. After the reload the NULL-ed records were
gone.

Yours

Ben Weeda



-----Oorspronkelijk bericht-----
Van: Ben Weeda <[EMAIL PROTECTED]>
Aan: [EMAIL PROTECTED] <[EMAIL PROTECTED]>
Datum: vrijdag 20 april 2001 11:58
Onderwerp: Autonumber problem


>Hello
>
>Has anybody got some good advice for me on this:
>R:Base database heavily used for about 3 years. Try to unload an reload.
>Error messages on autonumbering.
>1. There are autonumbering setting on columns that were not there when the
>database was developed.
>2. Error message " -Error- - is an invalid format character. (2522)
>3. Next value for an autonumber column is wrong
>When I look in SYS_DEFAULT table I find the trouble-making COLUMN_ID three
>times with different SYS_NEXT values.
>
>Question1: Can I delete two of the three entries without causing further
>trouble?
>Question2: How can autonumbering spontaneously grow on a column that did
not
>have it when designed. I'm pretty sure the users have not messed around in
>the database, because they use VB + Ottero and don't have R:Base on their
>machines.
>
>Yours
>
>Ben Weeda
>
>

Reply via email to