Thanks. I think I'm averaging around 40 amps based on the time my battery lasts in recent tests. So that's in line with your info.
On Dec 31, 12:13 pm, Frank Pittelli <[email protected]> wrote: > When operating at 12v, I used 30-40 amps as my normal operating current > estimate based on various measurements we made in the early days. Peak > current draws of 60-90 amps are possible when running EV Warriors at 12v > with excessive loading (such as improper gear ratio or when the motors > are stalled). Peak current draws are lower at 24v, but still large > enough to abuse SLA batteries. > > M01 geared motors typically draw 10-20 amps when moving a 120-150lb > tank. They are definitely more effective motors for our purposes, > providing excellent power and less abusive to batteries. > > Frank P. > > On 12/31/2010 10:20 AM, HV wrote: > > > > > For those of you using EV Warrior motors, either now or in years past, > > what is your experience of average amperage, and what voltage were you > > running them at?- Hide quoted text - > > - Show quoted text - -- You are currently subscribed to the "R/C Tank Combat" group. To post a message, send email to [email protected] To unsubscribe, send email to [email protected] Visit the group at http://groups.google.com/group/rctankcombat