Agreed on all points. I have a Classic 150 in my own system, running
1500W 36V in/24V out, for about six months. My first unit was a
Classic 200, which failed after a month in service - firmware issue
- and was promptly replaced by Midnite. While the replacement works
fine, I will wait for production datalogging and auto EQ before
using these in customers' systems. The logging of the MX60>FM60
spoiled me, once I had observable data to use for diagnosis, and to
show a customer, when on a troubleshooting call. I want it to reach prime time - to me, Robin has been a gem in our industry and deserves my support. The E-Panel is our default package for off-grid. I'd like the Classic to reach default status as well. Allan
Allan Sindelar
[email protected] NABCEP Certified Photovoltaic Installer NABCEP Certified Technical Sales Professional New Mexico EE98J Journeyman Electrician Positive Energy, Inc. 3201 Calle Marie Santa Fe, New Mexico 87507 505 424-1112 www.positiveenergysolar.com On 10/4/2011 5:07 PM, Jeff Oldham wrote:
|
_______________________________________________ List sponsored by Home Power magazine
List Address: [email protected] Options & settings: http://lists.re-wrenches.org/options.cgi/re-wrenches-re-wrenches.org List-Archive: http://lists.re-wrenches.org/pipermail/re-wrenches-re-wrenches.org List rules & etiquette: www.re-wrenches.org/etiquette.htm Check out participant bios: www.members.re-wrenches.org