Well again, I cant honestly advocate this as a best practice, its just how I do it most times :)

<set name="member" value="#application.recordFactory.createRecord('member').load(memberid=5)#" />

But something like that will return a member record of the  member with id = 5.  But the same thing could go for a gateway call.  Something like:

<set name="memq" value="#application.recordFactory.createGateway('member').getAll()#" />

And that would be based on you having initialized your reactor record factory and stored it in the application scope as recordFactory.  And the standard best practice I believe is to have your model circuit include act_ files that are appropriately named.  That way you can change the behaviour as you wish without having to muck up your xml.

HTH,

Simeon

On 8/15/06, Ray Buechler <[EMAIL PROTECTED]> wrote:
Simeon,

Could you give a quick example of how you do your set calls in your model circuit? I tried a while back and couldn't get it to work so I just started putting the Reactor calls into fuses.

Thanks,

Ray



-- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --