Tessco, Belden, other cable mfg's have, burried within their
websites, tables which give the loss factors of the 'standard'
feedlines at several frequencies, e.g. 100, 500, 1000 MHz

http://www.tessco.com/products/inv_display.jsp?gsg=40315&SA=Y

should take you to a fairly comprehensive list of cables from
the manufacturers Tessco represents.  (If the link is broken,
go to www.tessco.com, and click on "Transmission Line & Cable"
Then "Low Loss Cables," then "Show All Products"

General Rule: the smaller the cable, the less cost & more loss.

--- In [email protected], Budd Turner <[EMAIL PROTECTED]> 
wrote:
> 
> Happy Turkey Day All
> 
> Anyone know of a cost and performance comparison done on 
transmission lines out there?  ie. RG-58, RG-8x, RG-8, RG-213, 9913, 
LMR-200, LMR-400 etc....
> 
> 
> 
> ---------------------------------
> Do you Yahoo!?