Sean, All you have to do is replace the PA boards. Take the cast shield off the low pass filter. That gives you better access. Some people replace the medal strip between the PA & filter board with solder wick. Put a small hump in it to allow for heat expansion. Fred KF4QZN ----- Original Message ----- From: Sean KE6MOW Sent: Saturday, December 13, 2003 10:08 AM Subject: Re: [Repeater-Builder] GE Z Matcher umm... That didn't come out right.
Let's try that again. I am in the process of replacing a bad continues duty 100 watt PA with a boards from 75 watt mobile PA. I know that I have to replace the mobiles output filter with the Z matcher from the 100 watter. Is there more to it than this? Does the Z matcher require any tuning?
I've got a manual coming soon, but I'd like to get this thing back on the air.
Thanks, Sean
On Sat, 13 Dec 2003, Sean KE6MOW wrote:
> > I am in the process of replacing a bad continues duty 100watt PA with a > 75watt mobile PA. I know that I have to remove the mobile output filter > from the 100watter, but is there more to it than that? > > Thanks, > Sean > > > > > > > Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/ > > > >
Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/
Your use of Yahoo! Groups is subject to the Yahoo! Terms of Service.
|