--- In [email protected], Kevin Custer <[EMAIL PROTECTED]> wrote:
> Bob Dengler wrote:
> 
> >I believe ICM & Bomar only change these mid-range capacitors.
> >
> 
> I have purposely marked the TC caps in several MASTR II ICOM's and
MICOR 
> channel elements before sending them to BOMAR.  After they came back, 
> some units (in particular the GE ICOM's) had every TC capacitor 
> changed.  It's actually easy to spot, as BOMAR's uses caps that are a 
> nice blue color....

All those caps in the ICOMs make them a PITA to do my PTC thermistor
mod: they all have to come out!  I've only moded one ICOM so far & I'm
not sure I ever want to do another.  

Yet another reason for me to stick with MVPs, as the crystal modules
only have 1 temperature-compensating cap, if any.  Removing the
slightly temperature-sensitive varactor improves the stability even
further.

Bob NO6B







 