Do you have the diagnostic meter panel? I mean the one with all the LEDS? If not, you need to get one..
Steve Crumley wrote: > > > One of my 900Mhz MSF's is driving me nuts!. Every once in awhile it > will shut the PA down. I have been thru the usual checks for excessive > drive, SWR, connectors etc. It is a 75W PA, I will set the output to > 75W and then a few days later it will shut down. If I turn the power > control it will jump from zero to over 100 watts outand thats all. I > check the IPA and it is putting out 10 watts with no power control. > Then suddenly it will go back to normal. I can connect just the IPA to > a dummy load and its still in shut down. > > Does anyone have a mod to bypass this shut down feature. So I can just > set my power level where I want and let it run. > > Thanks > -- Jay Urish W5GM ARRL Life Member Denton County ARRL VEC N5ERS VP/Trustee Monitoring 444.850 PL-88.5