Do you have the diagnostic meter panel? I mean the one with all the LEDS?

If not, you need to get one..

Steve Crumley wrote:
> 
> 
> One of my 900Mhz MSF's is driving me nuts!. Every once in awhile it
> will shut the PA down. I have been thru the usual checks for excessive
> drive, SWR, connectors etc. It is a 75W PA, I will set the output to
> 75W and then a few days later it will shut down. If I turn the power
> control it will jump from zero to over 100 watts outand thats all. I
> check the IPA and it is putting out 10 watts with no power control.
> Then suddenly it will go back to normal. I can connect just the IPA to
> a dummy load and its still in shut down.
> 
> Does anyone have a mod to bypass this shut down feature. So I can just
> set my power level where I want and let it run.
> 
> Thanks
> 

-- 
Jay Urish W5GM
ARRL Life Member        Denton County ARRL VEC
N5ERS VP/Trustee        

Monitoring 444.850 PL-88.5