Did you check the logic level driving the PTT transistor ?
Does it change ?


 -------------- Original message ----------------------
From: "raritansailor" <[EMAIL PROTECTED]>
> Hi Folks,
> 
> I have an MCC RC-100 that I've been using for the MADXRA 147.345
> Repeater, here on the Panhandle of WV. Has been working just fine.
> 
> We decided to add a remote base in order to link this repeater into a 
> regional network. Everything hooked up fine, everything works fine, 
> EXCEPT.... I can't seem to get Remote Base Xmit to turn on! Therefore 
> no PTT to the link Xcvr.
> 
> I've programmed the 4066 * code 25 times and whenever I use it, no xmit 
> on! So as it stands I can turn remote base ON, get the 500Hz remote 
> base tone, the Link Xcvr audio is being passed from the network to the 
> 147.345 system, but you can't connect from the 147.345 repeater to the 
> network cuz the "Xmit on", won't turn on, and the Link Xcvr gets no PTT.
> 
> Any ideas folks? I DO program the 4066 * code with 0X where X is a "not 
> restricted" single digit. I've tried several different digits. (as a 
> side note ny * codes for "force ID", and "Remote base OFF" work just 
> fine!). When I program the 4066 * code I DO get the RR in response.
> 
> What am I missing? Anyone able to lend a suggestion?
> 
> Thanks!
> 
> Mike, N3EAQ
> 
> 
> 
> 
> 
>  
> Yahoo! Groups Links
> 
> 
> 

Reply via email to