Did you check the logic level driving the PTT transistor ? Does it change ?
-------------- Original message ---------------------- From: "raritansailor" <[EMAIL PROTECTED]> > Hi Folks, > > I have an MCC RC-100 that I've been using for the MADXRA 147.345 > Repeater, here on the Panhandle of WV. Has been working just fine. > > We decided to add a remote base in order to link this repeater into a > regional network. Everything hooked up fine, everything works fine, > EXCEPT.... I can't seem to get Remote Base Xmit to turn on! Therefore > no PTT to the link Xcvr. > > I've programmed the 4066 * code 25 times and whenever I use it, no xmit > on! So as it stands I can turn remote base ON, get the 500Hz remote > base tone, the Link Xcvr audio is being passed from the network to the > 147.345 system, but you can't connect from the 147.345 repeater to the > network cuz the "Xmit on", won't turn on, and the Link Xcvr gets no PTT. > > Any ideas folks? I DO program the 4066 * code with 0X where X is a "not > restricted" single digit. I've tried several different digits. (as a > side note ny * codes for "force ID", and "Remote base OFF" work just > fine!). When I program the 4066 * code I DO get the RR in response. > > What am I missing? Anyone able to lend a suggestion? > > Thanks! > > Mike, N3EAQ > > > > > > > Yahoo! Groups Links > > >