[EMAIL PROTECTED] wrote:
> Dear RB,
> I am putting together a 2 meter repeater and it will have a split site 
> configuration. I plan on linking the 2 meter RX with the 2 meter TX via 
> 440MHZ link. Has anyone done this which could help me with ideas about 
> how to identify the main 2 meter TX and the 440 link TX. Will I need to 
> hear redundant ID's? The only way I could come up with was to have two 
> separate repeaters, one with 2 meters in and 440 out, the other with 
> 440 in and 2 meters out and have separate controllers on each with 
> their own separate ID. Am I way off?
> Thanks, Collin
> 
> ------------------------------------

No. As long as an ID from the UHF link is repeated out on 2M, it's OK. 
Use as secure a link as you can though-ie, odd-ball freq, and a 
non-standard PL or DPL. Something that normal made-for-ham rigs won't 
do, to keep people from playing with it.