I am using a Zetron Model 48B as a repeater controller.  Everything is 
going fine except my addition of a Arcom RAD audio delay board.  The 
board is working great except now the CWID and status tones are not 
transmitted.

The RAD is tied to the COS coming from the receiver to act as a gate to 
eliminate squelch tails...........works great!  The RAD is inserted 
between the tx audio coming out of the panel and the input to the 
transmitter.

My problem is now the CWID and any audible status tones are not 
transmitted because they are gated by the RAD since the COS is not active. 

I am now trying to determine where inside the 48B I can gate the 
transmitted audio ahead of the CWID and status tones generated by the panel.

Anyone here know where to find such a location inside a 48B? 

Randy
WB0VHB