Was just curious as to if folks have
gotten Notch cavities to work ok with a 600khz
split.  Have 4 in Rx leg & 4 in TX leg.  According
to the analyzer, each bank has a >90dB notch.
Double shielded cable throughout (RG-9).

Just about pulled all my hair out over the last
couple of weeks, and still have desense issues.  
Even tried another repeater, just to see if it 
was still there, & yep it is. (was actually a
bit worse than the Quantar, but it uses cheesy
cables for RX (TKR-720)).

Did find something interesting inside the Quantar
tho, the RX cable that screws into the RX filter
housing had a problem.  They use a crimped Mini-UHF,
and the section that got crimped actually rotated
freely around the piece that has the center conductor
in it.  Nice rotatable cable, but don't think that
it was intended to do that!  Soldered the two together.

Thanks,

Tim  W5FN

Reply via email to