Andy

 

The attached will get you started with a repeater on port 1, and 3 remote
bases on 2 3 and 4.

 

There are no id's included, although the contents have a line that deletes
them.

 

Follow them with a new ID on the next line.

 

It has a cactus style beep boop - but you can change it to anything you
want.

 

Hang times are there for the repeater, but zero for ports 2 3 and 4.

 

You can reverse engineer these commands and put in the parameters that you
want to change, and then load this back in as an ascii file to the
controller.

 

Each time you want to change something, change the attached .txt file, and
upload it again.

 

Bill Hudson

W6CBS

 

 

 

From: [email protected]
[mailto:[email protected]] On Behalf Of Andrew Seybold
Sent: Saturday, February 13, 2010 2:19 PM
To: [email protected]
Subject: [Repeater-Builder] RLC-4 Controller

 

  

I am in the process of installing a new 6 Meter GE Mastr II repeater for our
radio club, it came with a pre-programmed RLC-4 controller since the package
was removed from service elsewhere. I don't loaded the software on the RLC-4
site but found out that I cannot use it to read the controller, only to
reprogram it for the new call sign etc. 

I am hoping that someone on here has figured out a way to import an existing
RLC-4 set-up data so that it can be modified and I don't have to go through
the entire programming from the beginning-anyone have experience with this?

 

Thanks

 

Andy W6AMS

 

cid:[email protected]

 <mailto:[email protected]> [email protected]

315 Meigs Road, Suite A-267
Santa Barbara, CA 93109
805-898-2460 office
805-898-2466 fax

 <http://www.andrewseybold.com> www.andrewseybold.com

 



<<image001.jpg>>

;Pineapple Radio Network RLC-4 Software Version 1.79
;
;February 16, 2005
;
;       This is a setup for a Big Island RLC-4 V 1.79
;
; Port 1 is a repeater
; Port 2 is a half duplex link
; Port 3 is a half duplex link
; Port 4 is a half duplex link
;
n045*0*                 Turn off CW responses to serial ports
; 
n000*11*                Port 1 a repeater
n002*22*                Port 2 no repeat
n002*33*                Port 3 no repeat 
n002*44*                Port 4 no repeat
;
n009*                   Display cross points
;
n005*11*                Port 1 is carrier access
n005*21*                Port 2 is carrier access
n005*31*                Port 3 is carrier access
n005*41*                Port 4 is carrier access
;
n007*11*                Port 1 Mutes TT 
n007*20*                Port 2 Passes TT 
n007*30*                Port 3 Passes TT
n007*40*                Port 4 Passes TT
;
n013*100*               Port 1 Cor act lo, PL act Lo
n013*210*               Port 2 Cor act Hi, PL act Lo
n013*300*               Port 3 Cor act Lo, PL act high
n013*400*               Port 4 Cor act Lo, PL act high
; 
;       Programming Timers
;
n020*04150              Courtesy Beep Delay 1.5 seconds after COR
n020*05150              Courtesy Beep Delay 1.5 seconds after COR
n020*06150              Courtesy Beep Delay 1.5 seconds after COR
n020*07150              Courtesy Beep Delay 1.5 seconds after COR
;        
n020*08500*             Port 1 hang time is 5 seconds
n020*09000*             Port 2 no hang time
n020*10000*             Port 3 no hang time
n020*11000*             Port 4 no hang time
;
;       Disable mini hang timers 
;
N020*190*               Port 1 mini hang timer off 
N020*200*               Port 2 mini hang timer off
N020*210*               Port 3 mini hang timer off
N020*220*               Port 4 mini hang timer off
;
;       Time out timers
; 
n020*52600*             Port 1 Rx TOT 10 minutes
n020*53600*             Port 2 Rx TOT 10 minutes
n020*54600*             Port 3 Rx TOT 10 minutes        
n020*55600*             Port 4 Rx TOT 10 minutes
;
n020*57003*             Port 2 h/dux link 3 second pre access tone
n020*58003*             Port 3 h/dux link 3 second pre access tone
n020*59003*             Port 4 h/dux link 3 second pre access tone
;
                Set Port 2 Preaccess tone to 400 Hz.
                Set Port 3 Preaccess tope to 400 Hz.
                Set Port 4 preaccess tone to 400 Hz.
;
                Port 1 config * preaccess with macro 170
                Port 2 config #04 preaccess, with tone in macro 171
                Port 3 config #04 preaccess, with tone in macro 172             
     
                Port 4 config #04 preaccess, with tone in macro 173
;
;       IDers
;        
;                       All CW speeds default at 20 wpm from factory
;                       All CW tone frequencies default to 1064 Hz.
; 
;               Set up Automatic IDs
;
n055*151        Delete Port 1 Initial ID        
n055*152        Delete Port 2 Initial ID
n055*153        Delete Port 3 Initial ID
n055*154        Delete Port 4 Initial ID
n055*155        Delete Port 1 Pending ID
n055*156        Delete Port 2 Pending ID
n055*157        Delete Port 3 Pending ID
n055*158        Delete Port 4 Pending ID


;
;       Courtesy Tones
;
n04111                  Enable Courtesy Beep Transmitter Port 1
n04120                  Disable Courtesy Beep Transmitter Port 2
n04130                  Disable Courtesy Beep Transmitter Port 3
n04140                  Disable Courtesy Beep Transmitter Port 4
;
;                       Serial Port Settings
n0600111                Set all settings to default values (9600 8-n-1)
;
;                       
n052*159*                       Delete Macro 159
n050*1590400070051633*  First Beep of 1633 Hz at 70
n053*1590400050051209*  Second Beep of 1209 Hz at 70
n020*04150*                     Port 1 Courtesy Beep delay 150
;
n052*160*               Delete Macro 160 Delete courtesy tone on port 2
n052*161*                       Delete Macro 161 Delete courtesy tone on port 3
n052*162*               Delete Macro 162 Delete courtesy tone on port 4
;
n032*10941*             Port 1 ID frequency 941 Hz.
n032*21064*             Port 2 ID frequency 1064 Hz.
n032*31064*             Port 3 ID frequency 1064 Hz.
n032*41064*             Port 4 ID frequency 1064 Hz.
; 
;       Last command
n045*01*                Turn on CW responses to serial commands to Port 1
n030*2420*               Send the CW "OK"
 

Reply via email to