Andy
The attached will get you started with a repeater on port 1, and 3 remote bases on 2 3 and 4. There are no id's included, although the contents have a line that deletes them. Follow them with a new ID on the next line. It has a cactus style beep boop - but you can change it to anything you want. Hang times are there for the repeater, but zero for ports 2 3 and 4. You can reverse engineer these commands and put in the parameters that you want to change, and then load this back in as an ascii file to the controller. Each time you want to change something, change the attached .txt file, and upload it again. Bill Hudson W6CBS From: [email protected] [mailto:[email protected]] On Behalf Of Andrew Seybold Sent: Saturday, February 13, 2010 2:19 PM To: [email protected] Subject: [Repeater-Builder] RLC-4 Controller I am in the process of installing a new 6 Meter GE Mastr II repeater for our radio club, it came with a pre-programmed RLC-4 controller since the package was removed from service elsewhere. I don't loaded the software on the RLC-4 site but found out that I cannot use it to read the controller, only to reprogram it for the new call sign etc. I am hoping that someone on here has figured out a way to import an existing RLC-4 set-up data so that it can be modified and I don't have to go through the entire programming from the beginning-anyone have experience with this? Thanks Andy W6AMS cid:[email protected] <mailto:[email protected]> [email protected] 315 Meigs Road, Suite A-267 Santa Barbara, CA 93109 805-898-2460 office 805-898-2466 fax <http://www.andrewseybold.com> www.andrewseybold.com
<<image001.jpg>>
;Pineapple Radio Network RLC-4 Software Version 1.79
;
;February 16, 2005
;
; This is a setup for a Big Island RLC-4 V 1.79
;
; Port 1 is a repeater
; Port 2 is a half duplex link
; Port 3 is a half duplex link
; Port 4 is a half duplex link
;
n045*0* Turn off CW responses to serial ports
;
n000*11* Port 1 a repeater
n002*22* Port 2 no repeat
n002*33* Port 3 no repeat
n002*44* Port 4 no repeat
;
n009* Display cross points
;
n005*11* Port 1 is carrier access
n005*21* Port 2 is carrier access
n005*31* Port 3 is carrier access
n005*41* Port 4 is carrier access
;
n007*11* Port 1 Mutes TT
n007*20* Port 2 Passes TT
n007*30* Port 3 Passes TT
n007*40* Port 4 Passes TT
;
n013*100* Port 1 Cor act lo, PL act Lo
n013*210* Port 2 Cor act Hi, PL act Lo
n013*300* Port 3 Cor act Lo, PL act high
n013*400* Port 4 Cor act Lo, PL act high
;
; Programming Timers
;
n020*04150 Courtesy Beep Delay 1.5 seconds after COR
n020*05150 Courtesy Beep Delay 1.5 seconds after COR
n020*06150 Courtesy Beep Delay 1.5 seconds after COR
n020*07150 Courtesy Beep Delay 1.5 seconds after COR
;
n020*08500* Port 1 hang time is 5 seconds
n020*09000* Port 2 no hang time
n020*10000* Port 3 no hang time
n020*11000* Port 4 no hang time
;
; Disable mini hang timers
;
N020*190* Port 1 mini hang timer off
N020*200* Port 2 mini hang timer off
N020*210* Port 3 mini hang timer off
N020*220* Port 4 mini hang timer off
;
; Time out timers
;
n020*52600* Port 1 Rx TOT 10 minutes
n020*53600* Port 2 Rx TOT 10 minutes
n020*54600* Port 3 Rx TOT 10 minutes
n020*55600* Port 4 Rx TOT 10 minutes
;
n020*57003* Port 2 h/dux link 3 second pre access tone
n020*58003* Port 3 h/dux link 3 second pre access tone
n020*59003* Port 4 h/dux link 3 second pre access tone
;
Set Port 2 Preaccess tone to 400 Hz.
Set Port 3 Preaccess tope to 400 Hz.
Set Port 4 preaccess tone to 400 Hz.
;
Port 1 config * preaccess with macro 170
Port 2 config #04 preaccess, with tone in macro 171
Port 3 config #04 preaccess, with tone in macro 172
Port 4 config #04 preaccess, with tone in macro 173
;
; IDers
;
; All CW speeds default at 20 wpm from factory
; All CW tone frequencies default to 1064 Hz.
;
; Set up Automatic IDs
;
n055*151 Delete Port 1 Initial ID
n055*152 Delete Port 2 Initial ID
n055*153 Delete Port 3 Initial ID
n055*154 Delete Port 4 Initial ID
n055*155 Delete Port 1 Pending ID
n055*156 Delete Port 2 Pending ID
n055*157 Delete Port 3 Pending ID
n055*158 Delete Port 4 Pending ID
;
; Courtesy Tones
;
n04111 Enable Courtesy Beep Transmitter Port 1
n04120 Disable Courtesy Beep Transmitter Port 2
n04130 Disable Courtesy Beep Transmitter Port 3
n04140 Disable Courtesy Beep Transmitter Port 4
;
; Serial Port Settings
n0600111 Set all settings to default values (9600 8-n-1)
;
;
n052*159* Delete Macro 159
n050*1590400070051633* First Beep of 1633 Hz at 70
n053*1590400050051209* Second Beep of 1209 Hz at 70
n020*04150* Port 1 Courtesy Beep delay 150
;
n052*160* Delete Macro 160 Delete courtesy tone on port 2
n052*161* Delete Macro 161 Delete courtesy tone on port 3
n052*162* Delete Macro 162 Delete courtesy tone on port 4
;
n032*10941* Port 1 ID frequency 941 Hz.
n032*21064* Port 2 ID frequency 1064 Hz.
n032*31064* Port 3 ID frequency 1064 Hz.
n032*41064* Port 4 ID frequency 1064 Hz.
;
; Last command
n045*01* Turn on CW responses to serial commands to Port 1
n030*2420* Send the CW "OK"