I believe you are talking about an Exec II. Several places to check before replacing the PA.
A common problem is the jumper between the exciter and the PA. The RCA connectors sometimes go intermittent. Also, if the TR relay hasn't been jumpered, it could have gone intermittent. Chuck WB2EDV ----- Original Message ----- From: "Larry Wagoner" <[email protected]> To: <[email protected]> Sent: Monday, September 06, 2010 8:27 PM Subject: [Repeater-Builder] 19D424089G1 > > > >>Anyone have one of the above they wish to part with? We have reason >>to suspect the PA in our repeater. > > It has developed various intermittent behaviors (dropping carrier, > distorted audio, varying output, etc.) .. > > I believe this to be the 60 watt PA for the GE Mastr II Exec II > mobile radio conversion. > If I have the wrong board number, please advise ... > > > > Larry Wagoner - N5WLW > PRCARC Training Officer > PIC - MS SECT ARRL > > > > ------------------------------------ > > > > Yahoo! Groups Links > > > -------------------------------------------------------------------------------- No virus found in this incoming message. Checked by AVG - www.avg.com Version: 9.0.851 / Virus Database: 271.1.1/3117 - Release Date: 09/06/10 02:35:00