PS2, Line 997:       if (ran) {
> The flag has no validator, so --auto_leader_rebalancing_interval_seconds=0
Thanks for pointing this out! I went with the clamp. The interval is read once 
per iteration now and floored at a second, so one value drives both the due 
check and the poll, which also folds away the double read you noticed.

I preferred that over a validator because the flag is runtime-tagged, so a 
validator would start rejecting set_flag calls and startup configs that are 
accepted today.



--