On 2007-09-24, Nuno Fernandes <[EMAIL PROTECTED]> wrote:
>>
>> With engenio/rdac that's what you have if you're lucky, but you might
>> just as well be unlucky and get:
>>
>> (a) HBA1 ====== DS4x00 controller A  ==== LUNx
>> (b) HBA1 ====== DS4x00 controller B  ==== LUNx
>> (c) HBA2 ~~~~~~ DS4x00 controller A  ~~~~ LUNx
>> (d) HBA2 ~~~~~~ DS4x00 controller B  ~~~~ LUNx
>
> I've disabled AVT (Automatic Volume Transfer) in DS4700. I can't have two 
> active paths to the same LUNx using both controllers.

Oops, my bad. I intended to write LUNx/LUNy/LUNx/LUNy.


>> I'm not familiar with EMC Clariion... but have hit this exact same
>> problem on IBM DS4800/RDAC.
> How did you solve it? :)
>

Followed the RDAC readme and avoided seeing both controllers on same HBA.
I even think it looks like a good thing to keep both FC switches
completely separated. Then a misconfiguration on one can't propagate
to the other.