On 2007-09-25, Nuno Fernandes <[EMAIL PROTECTED]> wrote:

> I also have both FC switches completly separated. 
>
>                                | -> Controller A
> HBA A -> SwitchA  |
>                                | -> Controller B
>
>                               |  -> Controller A
> HBA B -> SwitchB |
>                               |  -> Controller B

No, these switches are connected trough the DS-controllers, 
and not completely separated. Problems on f.ex. HBA-B could
propagate to both controllers, or HBA-A.

Can you try this setup and see if it solves your problem ?

HBA A -> SwitchA  | | -> Controller A

HBA B -> SwitchB  | | -> Controller B

You'll still have fully redundant paths to any LUN.


  -jf