Hi All,

I am trying to fit a large unknown amorphous phase. It is not being properly 
fit by my background and being fit by broadening out the peaks of other small 
phases present that should be crystalline. I did XRD-CT on a lead pipe scale 
material and so I cannot spike the sample with a known weight percentage of 
material with a similar absorption coefficient. Is there any way that I can fit 
this unknown phase as just a general unknown amorphous material and exclude it 
from the weight percent calculation?

Thanks,
Claire

++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
Please do NOT attach files to the whole list <[email protected]>
Send commands to <[email protected]> eg: HELP as the subject with no body text
The Rietveld_L list archive is on http://www.mail-archive.com/[email protected]/
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++

Reply via email to