On Mon, 3 Feb 2014, Cowboy wrote:
On Monday 03 February 2014 12:14:01 pm Jim Stewart wrote:
You can NEVER physically bridge outputs in the real world.
No, but if they're transformer-balanced, you can connect them in series.
If they're active differential outputs, you can connect one side of your
load to the + side of output #1, and the other side of the load to the -
side of output #2.
Of course, that only works if the two sources have a common ground
reference.
Rob