On Dec 4, 2014, at 13:13 50, Michael Barnes <[email protected]> wrote:

> We are installing a new SAS 32KD switcher.  It's a big one with three frames. 
>  We use RDCATCH to send commands to the switcher to route audio from place to 
> place.  In setting up a switching event, Rivendell only allows us to go up to 
> 1024 channels.  We have 1536 channels.  Is there a patch or anything we can 
> get to allow more than 1024 channels?

You can change this by adjusting the value of the ‘MAX_ENDPOINTS’ define in 
‘lib/rd.h’ and recompiling.


>  We installed the latest appliance DVD.  We noticed in the switcher setup the 
> SAS 64000 is listed but not the 32KD.

You want the SAS USI driver.  See the 'Sierra Automated Systems Universal 
Serial Interface (USI)’ section in
https://github.com/ElvishArtisan/rivendell/blob/master/docs/SWITCHERS.txt.

Cheers!


|----------------------------------------------------------------------|
| Frederick F. Gleason, Jr. |              Chief Developer             |
|                           |              Paravel Systems             |
|----------------------------------------------------------------------|
|          A room without books is like a body without a soul.         |
|                                         -- Cicero                    |
|----------------------------------------------------------------------|

_______________________________________________
Rivendell-dev mailing list
[email protected]
http://caspian.paravelsystems.com/mailman/listinfo/rivendell-dev