On Dec 11, 2014, at 13:55 30, Michael Barnes <[email protected]> wrote:

> We found the file and made the change in ENDPOINT.  But a quick check of the 
> serial output show it is still only outputting three digits, where we need 
> four.  It is also not outputting the proper prefix code.  It only outputs ^T 
> while we need it to send out ^ET for switching four digits.  Any ideas on 
> where we can fix this?

Ah, looks like SAS has made an extension to their command protocol.  The SAS 
USI driver would need to be modified to support this.

Cheers!


|----------------------------------------------------------------------|
| Frederick F. Gleason, Jr. |              Chief Developer             |
|                           |              Paravel Systems             |
|----------------------------------------------------------------------|
|          A room without books is like a body without a soul.         |
|                                         -- Cicero                    |
|----------------------------------------------------------------------|

_______________________________________________
Rivendell-dev mailing list
[email protected]
http://caspian.paravelsystems.com/mailman/listinfo/rivendell-dev

Reply via email to