On Nov 30, 2018, at 09:50, Gabriele Fergola <[email protected]> wrote:
> When i set it to -10dB and some value from 0 to 3000 nothing changing. The
> marker are always at same position and are inverted like start is after end.
> What i'm doing wrong?
>
> i have also normalization (-13dB) and Trim (-30dB) active.
From the rdimport(1) man page (emphasis added):
*** snip snip ***
--segue-level=level
Specify the threshold level to use for setting the segue start
marker, in dBFS, as measured *after* any specified normalization has
been applied. Default action is not to create segue markers.
*** snip snip ***
You’re normalizing to -13 dB, thus your threshold for segue-marker creation
(-10 dB) can never be reached. Try --segue-level=-23 instead.
Cheers!
|----------------------------------------------------------------------|
| Frederick F. Gleason, Jr. | Chief Developer |
| | Paravel Systems |
|----------------------------------------------------------------------|
| Opportunity is missed by most people because it is dressed in |
| overalls and looks like work. |
| -- Thomas Edison |