Salut,
Am un server vechi HP cu un RAID5 cu un disk defect. L-am schimbat fizic cu
unul nou, dar array-ul nu vrea să se refacă. Am instalat hpacucli și pot să
văd starea array-ului și a discurilor:

[root@Tassadar adrianp]# hpacucli
HP Array Configuration Utility CLI 9.20.9.0
Detecting Controllers...Done.
Type "help" for a list of supported commands.
Type "exit" to close the console.

=> ctrl slot=0 logicaldrive all show status

   logicaldrive 1 (136.7 GB, RAID 1): OK
   logicaldrive 2 (1.4 TB, RAID 5): Interim Recovery Mode
=> controller slot=0 show config

Smart Array P410i in Slot 0 (Embedded)    (sn: 500143800891C3B0)

   array A (SAS, Unused Space: 0  MB)


      logicaldrive 1 (136.7 GB, RAID 1, OK)

      physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 146 GB, OK)
      physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 146 GB, OK)

   array B (SAS, Unused Space: 0  MB)


      logicaldrive 2 (1.4 TB, RAID 5, Interim Recovery Mode)

      physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 300 GB, Predictive
Failure)
      physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 300 GB, OK)
      physicaldrive 2I:1:5 (port 2I:box 1:bay 5, SAS, 300 GB, Failed)
      physicaldrive 2I:1:6 (port 2I:box 1:bay 6, SAS, 300 GB, OK)
      physicaldrive 2I:1:7 (port 2I:box 1:bay 7, SAS, 300 GB, OK)
      physicaldrive 2I:1:8 (port 2I:box 1:bay 8, SAS, 300 GB, OK)

   SEP (Vendor ID PMCSIERA, Model  SRC 8x6G) 250 (WWID: 500143800891C3BF)

Am încercat să scot discul 1:5, dar nu mă lasă:
=> controller slot=0 array B remove drives=1:5

Error: This operation is not supported with the current configuration. Use
the
       "show" command on devices to show additional details about the
       configuration.
Reason: Array is transforming

Aveți o sugestie ce ar trebui să-l fac să recitească discul din 1:5 și să
facă rebuild?

Mulțumesc.
_______________________________________________
RLUG mailing list
RLUG@lists.lug.ro
http://lists.lug.ro/mailman/listinfo/rlug_lists.lug.ro

Raspunde prin e-mail lui