Am făcut o fereastră de mentenanță și am luat următoarele acțiuni:
1. Reboot server cu HDD scos - îl vedea ca failed 0M:
=> controller slot=0 show config
Smart Array P410i in Slot 0 (Embedded) (sn: 500143800891C3B0)
array A (SAS, Unused Space: 0 MB)
logicaldrive 1 (136.7 GB, RAID 1, OK)
physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 146 GB, OK)
physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 146 GB, OK)
array B (SAS, Unused Space: 0 MB)
logicaldrive 2 (1.4 TB, RAID 5, Interim Recovery Mode)
physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 300 GB, Predictive
Failure)
physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 300 GB, OK)
physicaldrive 2I:1:5 (port 2I:box 1:bay 5, SAS, 0 MB, Failed)
physicaldrive 2I:1:6 (port 2I:box 1:bay 6, SAS, 300 GB, OK)
physicaldrive 2I:1:7 (port 2I:box 1:bay 7, SAS, 300 GB, OK)
physicaldrive 2I:1:8 (port 2I:box 1:bay 8, SAS, 300 GB, OK)
SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250 (WWID: 500143800891C3BF)
=>
2. Inserat disc - nu vedea nimic la rescan așa că am mai dat un restart de
server, iar acum:
=> controller slot=0 show config
Smart Array P410i in Slot 0 (Embedded) (sn: 500143800891C3B0)
array A (SAS, Unused Space: 0 MB)
logicaldrive 1 (136.7 GB, RAID 1, OK)
physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 146 GB, OK)
physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 146 GB, OK)
array B (SAS, Unused Space: 0 MB)
logicaldrive 2 (1.4 TB, RAID 5, Recovering, 9% complete)
physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 300 GB, Predictive
Failure)
physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 300 GB, OK)
physicaldrive 2I:1:5 (port 2I:box 1:bay 5, SAS, 300 GB, Rebuilding)
physicaldrive 2I:1:6 (port 2I:box 1:bay 6, SAS, 300 GB, OK)
physicaldrive 2I:1:7 (port 2I:box 1:bay 7, SAS, 300 GB, OK)
physicaldrive 2I:1:8 (port 2I:box 1:bay 8, SAS, 300 GB, OK)
SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250 (WWID: 500143800891C3BF)
Să sperăm că nu crapă celelalte acum :D
Mulțumesc de ajutor!
On Fri, Aug 17, 2018 at 1:09 PM Petru Rațiu <[email protected]> wrote:
> On Fri, Aug 17, 2018 at 12:34 PM Alex 'CAVE' Cernat <[email protected]>
> wrote:
>
> > On 17-Aug-18 11:18 AM, Adrian Popa wrote:
> > > logicaldrive 2 (1.4 TB, RAID 5, Interim Recovery Mode)
> > >
> > > physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 300 GB,
> Predictive
> > > Failure)
> > > physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 300 GB, OK)
> > > physicaldrive 2I:1:5 (port 2I:box 1:bay 5, SAS, 300 GB, Failed)
> > > physicaldrive 2I:1:6 (port 2I:box 1:bay 6, SAS, 300 GB, OK)
> > > physicaldrive 2I:1:7 (port 2I:box 1:bay 7, SAS, 300 GB, OK)
> > > physicaldrive 2I:1:8 (port 2I:box 1:bay 8, SAS, 300 GB, OK)
> > >
> > ai mare grija ca si discul din portul 3 e pe moarte, oare de asta sa nu
> > porneasca rebuildul ? totusi e un non-sense
> >
>
> Eu mai avusesem probleme similare cu raiduri hw cu discuri busite si tin
> minte ca a trebuit sa-i dau $ceva ca sa se prinda ca am schimbat discul si
> sa-l reinitializeze; speram ca se gaseste cineva care stie mai bine
> detaliile ca mine :)
>
> --
> P.
> _______________________________________________
> RLUG mailing list
> [email protected]
> http://lists.lug.ro/mailman/listinfo/rlug_lists.lug.ro
>
_______________________________________________
RLUG mailing list
[email protected]
http://lists.lug.ro/mailman/listinfo/rlug_lists.lug.ro