HI Huaimo, Thanks for the reply. In this case, I'd suggest adding some clarification text as this repair node needs to have SRv6 encapsulation capability, not just forwarding, and it might be hops away from the egress node.
Thanks, Yingzhen On Thu, Oct 26, 2023 at 1:22 PM Huaimo Chen <[email protected]> wrote: > Hi Yingzhen, > > > > Thank you very much for your question. > > Your understanding is right. > > > > Best Regards, > > Huaimo > > *From:* Yingzhen Qu <[email protected]> > *Sent:* Wednesday, October 25, 2023 9:03 PM > *To:* [email protected]; RTGWG < > [email protected]> > *Subject:* Question for draft-ietf-rtgwg-srv6-egress-protection > > > > Hi authors, > > > > (As an individual contributor) > > > > In section 3.1.1: > > Step 2d: P1 as PLR Prepares to Protect PEA by PEB > > > > My question is how to pick the PLR router? My understanding is that it > should be the endpoint next to PEA. Please correct me if I'm wrong. > > > > Thanks, > > Yingzhen >
_______________________________________________ rtgwg mailing list [email protected] https://www.ietf.org/mailman/listinfo/rtgwg