Karl Reichert wrote:
Jan Kiszka wrote:
Roland Tollenaar wrote:
Hi,
then I must have 2 Ethernet lines. Is it true ?
correct

My PC-based controller has two Ethernet lines handled by 2 chips of the
same type (8139too).

Is it possible to configure one line for RTnet and the other for non-real time linux environment ?
no problem.

 > What can I do to obtain this goal ?

rmmod the non-realtime driver, load and start rtnet on a card (see script fragment below) then load the non-realtime module and bring it
up.

Pushing this FAQ into the wiki would be highly appreciated. :)


Done: 
http://www.xenomai.org/index.php/RTnet:Installation_%26_Testing#Using_realtime_.28RTnet.29_and_non-realtime_network_together

Thanks at lot!

Jan


Attachment: signature.asc
Description: OpenPGP digital signature

-------------------------------------------------------------------------