On Wed, 26 Sep 2018 15:02:10 +0900,
Wilson José Siqueira wrote:
> Is it possible to redirect a in-band communication switch-controller to
> another port (or link) in case of a traffic congestion or another kind of
> problems, like errors or delay into OpenFlow Channel?
> 
> I saw in 6.3.1 Connection Setup, OpenFlow Switch Specification, Version
> 1.3.0 (Wire Protocol 0x04) that:
> 
> "Traffic to and from the OpenFlow channel is not run through the OpenFlow
> pipeline."
> 
> So how can I perform this change in OpenFlow Channel?
> Is it possible with another OpenFlow version?

I'm not quite sure how you are planning to use flows to solve the
problem, but in-band OpenFlow connections are just like normal traffic
AFAIK.

The language of the section 6.3 seems to have changed between spec
versions 1.3 and 1.3.5.

--
IWAMOTO Toshihiro


_______________________________________________
Ryu-devel mailing list
Ryu-devel@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/ryu-devel

Reply via email to