OK, I think I've got it. For some reason the scanner is not happy with
the default resolution of 150dpi. I can use 100, 200, 300 and I get a
correct image.
So, for the benefit of anyone else trying to use this scanner you need
to have
option disable-gamma-table
option resolution 100
in your avision.conf config file.