On 07/09/18 20:40, Simon J. Rowe wrote:
OK, I think I've got it. For some reason the scanner is not happy with
the default resolution of 150dpi. I can use 100, 200, 300 and I get a
correct image.
So, for the benefit of anyone else trying to use this scanner you need
to have
option disable-gamma-table
option resolution 100
in your avision.conf config file.
Simon
No, that second line doesn't work, you have to pass "--res 100" to
scanimage. I think I'll patch my build to make that the default,
Simon
--
sane-devel mailing list: [email protected]
https://alioth-lists.debian.net/cgi-bin/mailman/listinfo/sane-devel
Unsubscribe: Send mail with subject "unsubscribe your_password"
to [email protected]