Tomislav Renic wrote: > > Sorry about the lack of details. I realized after I sent the email that I > should have been a bit more explicit with my system details. Here's what > I've got: > > Sun Ultra 10 with 300 MHz Ultrasparc IIi > Adaptec AHA2940UW Controller at SCSI-ID=7 > UMAX S6E scanner on SCSI-ID=5 > Debian Linux with kernel 2.4.7 using loadable modules for aha7xxx.o and sg.o > sane version 1.0.5 (I tried both the debian precompiled packages and rolling > my own...same problem) > Shared libraries are indeed supported > I could use xscanimage if I sane could recognize the scanner. > > Here's the debug output from the mustek backend: > debian:~# SANE_DEBUG_MUSTEK=4 scanimage -L > [sanei_debug] Setting debug level of mustek to 4. > [mustek] SANE mustek backend version 1.0 build 107 from sane-backends-1.0.5 > [mustek] sane_init: reading config file `mustek.conf' > [mustek] sane_init: config file line 4: strip-height set to 1 inches > [mustek] sane_init: config file line 10: trying to attach `scsi MUSTEK * > Scanner' > [mustek] sane_init: config file line 14: option lineart-fix ignored, was set > before any device name > [mustek] sane_init: config file line 16: trying to attach `scsi SCANNER' > [mustek] sane_init: config file line 20: option lineart-fix ignored, was set > before any device name > [mustek] sane_init: config file line 22: trying to attach `/dev/scanner' > [mustek] attach: trying device /dev/scanner > [mustek] dev_open: /dev/scanner is a SCSI device > [mustek] dev_open: wanted 8 kbytes, got 8 kbytes buffer > [mustek] attach: inquiry for device /dev/scanner failed (Error during device > I/O)
Tomislav, this sounds like a like a problem somewhere in sanei_scsi or below. Could you run another test with SANEI_DEBUG_SANEI_SCSI=255 ? (BTW, since you are using a Umax scanner, setting SANE_DEBUG_UMAX might be more reasonable than SANE_DEBUG_MUSTEK. But since all backends for SCSI scanners issue the INQUIRY command, you'll probably see a similar message from the Umax backend.) Abel