(cc'd to sane-devel) Hi,
On Sun, Nov 11, 2001 at 12:56:28PM -0600, Steven Lembark wrote: > Sorry about that, bad paste. /opt/sane.d -> /opt/sane/etc/sane.d > and everything from /opt/sane/1.06 is soft linked up one level > (makes it easier to change versions, just replace a few soft links). I think something went wrong with the links somewhere or with SANE installation because: > root@dizzy:bin # ./scanimage -L > [sanei_debug] Setting debug level of dll to 255. > [dll] sane_init: SANE dll backend version 1.0.4 from sane-backends-1.0.6 > > No scanners were identified. If you were expecting something different, > <snip> > [dll] sane_exit: exiting This means that libsane-dll.so was found. Otherwise the [dll] messages wouldn't be printed. So I think the libraries are found. However, dll doesn't even try to find the backend libraries. The only reason I can think of is that dll can't find the file dll.conf. You can set the config directory manually: export SANE_CONFIG_DIR=/opt/sane/1.0.6/etc/sane.d/ Then try scanimage again. I will add an error message to dll.c if no config file is found. > Both the frontend and backend were configured with > "--prefix=/opt/sane/1.0.6", > which is what the sane-config seems to be telling me. After that is was > "make all install", which wouldn't have installed unless the make succeeded. Usually this works. That's the way I test SANE on AIX, Irix and Solaris where I'm not root (./configure --prefix=/tmp/sane-bin). > Nope. Would be helpful in the linux notes if there were an example > of manhandling any specific output of /proc/scsi/scsi into a specific > > scsi VENDOR MODEL TYPE BUS CHANNEL ID LUN > > entry. Looking at the original notes I'd have thought that > "VENDOR" should have been "BusLogic" or "Adaptec" rather than > the scanner mfr. I will see if I can change the text to make it clearer. > I'm also not sure from the above where to put > the card sequence (in this case my BusLogic is the 2nd scsi card): > > /dev/scsi/host2/bus0/target1/lun0/generic Is this a devfs entry? > and its /proc/scsi/scsi entry is: > > Host: scsi2 Channel: 00 Id: 01 Lun: 00 > Vendor: HP Model: C2520A Rev: 3644 > Type: Processor ANSI SCSI revision: 02 > > The entry: > > scsi 'HP' 'C2520A' 'Processor' 0 0 1 0 > > leaves out that this is on the 2nd controller (scsi2 in the /proc > entry, host2 in /dev/scsi). Usually you only need "scsi HP" or "scsi HP C2520A". The other options are only necesarry if you have more than one identical scanner and want to access a specific one. Bye, Henning