Hi all, I got a report from a Mustek scanner user who can't use his scanner since SANE 1.0.7. The SCSI bus resets during the lamp warm-up.
The logfiles show that calibration sometimes take more than 60 seconds. That's the timeout set in sanei_scsi.c since 1.0.7. I use a similar scanner and had such a reset once or twice in the past but I couldn't really reproduce it. The lamp warm-up occurs during calibration, there is no way to avoid the timeout in the abckend as far as I know. The warm-up times vary between 10 seconds and 78 seconds for unknown reasons. Can we change the standard timeout value from 60 seconds to 90 or even 120 seconds? Or even better: is tehre a way to set the timeout by the backend? Bye, Henning