Hi, On Sun, Sep 01, 2002 at 10:02:07PM +0200, abel deuring wrote: > currently there is no way to change the timeout value programatically. > (one more issue that should be fixed in Sane 2) I think that increasing > the default timeout value is not a problem, unless we return to the > _really_ long value of 10 minutes, as we had it before. It's simply too > boring to wait for 10 minutes until you get an error ;) > > Perhaps we could use an enviroment variable to increase or decrease the > timeout -- just in case that we have again a too short timeout value for > some scanners...
That's a good idea. So we change SANE_SCSICMD_TIMEOUT to a static variable (e.g. sane_scsicmd_timeout) throughout the code that is initialized by 60. If variable SANE_SG_TIMEOUT is set, sane_scsicmd_timeout is changed appropriately, e.g. in sanei_scsi_open. Can you do that? You are a lot more familiar with the SCSI code :-) Bye, Henning