Hi, > [sanei_usb] sanei_usb_read_bulk: wanted 8 bytes, got 8 bytes > [snapscan] usb_read: reading: 0xfb 0x00 0x00 0x00 0x00 0x00 0x00 > 0x00 [snapscan] Read 8 bytes > [snapscan] sense_handler(0, 0xbfe23280, 0x9c40a88) > [snapscan] sense_handler: sense key: 0x04, asc: 0x00, ascq: 0x00, > i1: 0x80, i2: 0x00 > [snapscan] sense_handler: Hardware error. (0x80, 0x00) > [snapscan] scsi_read: snapscan_cmd command failed: Error during > device I/O
According to my docs the error code indicates a "lamp, CCD or gain error" - whatever that means. It seems to occur immediately after reading the first block of image data. Is the lamp turned on at all? /Oliver