On Freitag, 4. Mai 2007, Gerhard Jaeger wrote: > On Freitag, 4. Mai 2007, Johannes Meixner wrote: > > > > Hello, > > > > I got a strange bug report from a user: > > https://bugzilla.novell.com/show_bug.cgi?id=269921 > > > > Short summary: > > He uses a HP ScanJet 2200C USB scanner with the plustek backend. > > Scanning via scanimage works well. > > But scanning via xscanimage/xsane/kooka results the right side > > be tinted redly, and the left greenly, see > > https://bugzilla.novell.com/attachment.cgi?id=136721&action=view > > In kooka even the prescan is okay. > > > > Hi, > > I think this is covered by bug report #304296. The problem > is the x86_64 architecture - or my coding stuff ;) > Guess the problem is somewhere located in the calibration > code. > As I don't have such a system, I first need to get one > for testing. The difference between scanimage and xsane > could be the calibration cache. Disabling that should > make the stuff work. > > - Gerhard
In the meantime, I had the chance to test a bit on a Debian x86_64 box (AMD Sempron) and this one had no problems. I've tested with a HP2200c, scanimage and xsane - nothing. I've recompiled the current CVS stuff - no problems so far. I did the tests also with my LiDE20 and LiDE30 - also no problems. Tests have been done with and without the calibration cache. Ciao Gerhard